Haier ESA412K Manuel d'utilisateur Page 154

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 259
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 153
CIRCUIT DIAGRAM OF INDOOR UNIT
0010576548
(FREEZE)
CN8
SW2
BL
P13
(HUMI)
(PUMP)
(HEAT)
Y
(L)
(FRESH)
P8 P9
P7
P12
P10
P11
(COMM)
W
(N')
(M)
(H)
SW3
P17
(L')
P14
P15
SW5
SW4
P16
CN4
CN5
CN1
TRANS.
SWITCH
(DOOR)
(CONTROLLER)
WIRED
CONTROLLER
(FLOAT)
CN15
CN13
(UP-DOWN)
CN14
A
B
(ALARM)
CN16
(REMOTE)
CN11
CN12
FLOAT
REMOTE
RECEIVER
REMOTE
ON
12
ON
1234
CN19
CN20
4
W:WHITE B:BLACK
R:RED Y:YELLOW
OR:ORANGE BL:BLUE
BR:BROWN
Y/G:YELLOW/GREEN
CAP.:FAN MOTOR CAPACITOR
FC:FAN MOTOR SPEED
CONTROLLER
TRANS.:TRANSFORMER
CONTROLLER
CENTRALIZED
(RECEIVE BOARD)
(SWING)
(OXYGEN)
3
1
10
FC
CN21
CN7
FUSE
T3.15A/250VAC
P4(N2)
TO OUTDOOR UNIT
P5(N3)
R
2
3
1
B
W
W
R
B
W
B
P1(L)
P2(N)
P3(N1)
R
P6(N4)
SW1
(ROOM/PIPE)
CN6
TEMP.
SENSOR
SENSOR
PIPING TEMP.
ROOM
8
6
Y/G
Y/G
9
2
CAP.
Y/G
M
ON
1234
ON
1234
ON
1234
5. REFER TO OPERATION MANUAL TO SET SW1-SW5
1. PARTS 1 2 3 4 5 IN DASHED FRAME ARE NOT AVAILABLE
2.PARTS 6 7 8 ARE OPTIONAL
3. PART 9 IS FAN MOTOR SPEED CONTROLLER KIT
4. PARTS 10 AND CONNECTED DASHED LINES ONLY AVAILABLE IN AD88NAHBEA
5
COM
NO
NC
COM
NO
NC
COM
8
6
4
2
5
3
1
7
8
6
4
2
5
3
1
7
8
6
4
2
5
3
1
7
NO
NC
CAP.
Y/G
M
7
FAN MOTOR
FAN MOTOR
NOTE:
CN17
(12V/ALM)
>a__WcU[S^ <[c >a`V[e[a`Wc
Note: for the above indoor units, the PCB code is 0010451690E / 0010451167E, the detail information
please refers to page 53 and page 54.
CIRCUIT DIAGRAM OF INDOOR UNIT
0150500547
(FREEZE)
CN33
BL
CN8
(PUMP)
(HEAT)
Y
(L)
(FRESH)
CN12
CN13
CN9
CN1
CN10
(COMM)
W
(N')
(M)
(H)
CN31
(L')
CN7
CN21
SW3
SW4
CN30
CN18
CN20
CN17
TRANS.
SWITCH
(DOOR)
WIRED
CONTROLLER
(FLOAT)
CN24
CN26
(UP-DOWN)
CN25
A
B
(ALARM)
CN34
(REMOTE)
CN23
CN22
FLOAT
REMOTE
RECEIVER
ON
12
ON
1234
CN16
UP-DN L-R
CN15
3
W:WHITE B:BLACK
R:RED Y:YELLOW
OR:ORANGE BL:BLUE
BR:BROWN
Y/G:YELLOW/GREEN
CAP.:FAN MOTOR CAPACITOR
TRANS.:TRANSFORMER
(RECEIVE
BOARD)
(SWING)
(OXYGEN)
OR
YY
M
SWING
MOTOR
FAN MOTOR
2
12
1
6
8
9
7
CN27
CN14
FUSE
CN2(N2)
M
CN5(N3)
TO OUTDOOR UNIT
R
231
B
W
W
R
B
W
B
OR
CN1(L)
CN4(N)
CN3(N1)
MOTOR
MOTOR
SWING
PUMP
R
CN6(N4)
(ROOM/PIPE)
CN32
TEMP.
SENSOR
SENSOR
PIPING TEMP.
ROOM
4
5
Y/G
Y/G
10
14
13
M
M
CAP.
Y/G
Y/G
M
11
CAP.
M
SW2
SW1
ON
1234
ON
1234
6.
PARTS AND
CONNECTED
WIRES IN DASHED FRAME
12 13 ONLY AVAILABLE IN AC***AFBEA TYPE
7. IN ******BIA OR ******ERA TYPE, THE FUSE TYPE IS T3.15A/250VAC
8. REFER TO OPERATION MANUAL TO SET SW1-SW4
1. PARTS 1 2 3 IN DASHED FRAME ARE NOT AVAILABLE
2. PARTS 4 5 6 ARE OPTIONAL, AND THE LINE MARKED 14 ONLY AVAILABLE IN CONVERTIBLE TYPE
3. PARTS AND CONNECTED WIRES IN DASHED FRAME 7 9 ARE NOT
AVAILABLE
IN CONVERTIBLE TYPE,
AND ALSO NOT
AVAILABLE
IN AD***AMBEA(ECO) ,
AND CORRESPONDINGLY THERE IS A CLIP ON PCB
4. PARTS AND CONNECTED WIRES IN DASHED FRAME 8 ARE NOT AVAILABLE IN DUCT TYPE
5. PARTS AND CONNECTED WIRES IN DASHED FRAME 10 11 DETERMINED BY PRODUCTS TYPE
CN28
(12V/ALM)
NOTE:
REMOTE
CONTROLLER
CENTRALIZED
T3.15A/250VAC
AC362AFERA
AD282/362/482/602AHEAA
-154-
Vue de la page 153
1 2 ... 149 150 151 152 153 154 155 156 157 158 159 ... 258 259